APPENDICES
Orion Installation and Operations Manual
41
Appendix A General Specifications
Power Supply Voltage AC: 90-240VAC-0.5A-47-63Hz
Power required 230V/2000mA 115V/4000mA
Interfaces RJ45 (INTERCONNECT) 1000 Mbit High-speed transmission.
Wiring acc. EIA/TIA 568B Gigabit Ethernet
LC (Glass Fiber) 1000 Mbit High-speed transmission.
Corresponds to Gigabit Ethernet
RJ45 ETHERNET Standard ETHERNET access for HTTP, FTP, TELNET
(Control Port)
DB9 Serial 115.2 KBAUD, 8 data bits, 1 Stop bit, NO parity
(Control Port) Limited Hardware Handshake (DSR)
CATx Cable Length CATx installation cable 140m (400ft) - AWG24 (solid cable)
CATx patch cable 70m (200ft) - AWG26/8 (stranded cable)
Type of Interconnection Cable CATx installation cable AWG24 (solid cable)
S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 24.
Wiring acc. EIA/TIA 568A 1000BaseT).
CATx patch cable AWG26/8 (stranded cable)
S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or
Digital STP 17-03170. Four pairs AWG 26/8. Wiring
acc. EIA/TIA 568A (1000BaseT).
Maximum Length of Fiber Cable Singlemode 9 μm 10.000m (32.750ft)
Multimode 50μm 400m (1.300ft)
Multimode 62.5μm 200m (650ft)
Size and Shipping Weight 483 x 85 x 450mm (19”/2U x 18”)
Weight (typical): 6kg (12.9lb)
Environmental Operating Temperature 41 to 113°F (5 to 45 °C)
Storage Temperature -13 to 140°F (-25 to 60 °C)
Relative Humidity max. 80% non-condensing
Serial link: Serial Speed: Any up to a maximum of 19,200 Baud
Serial Data Format: Format independent
Flow Control: RTS, CTS, DTR, DSR are sent across link
Audio link:
Description: Bi-directional stereo audio link
Transmission Method: Digitized virtually CD quality audio (16-bit, 38.4 KHz)
Signal Levels: Line-Level (5 Volts P-P maximum)
Input Impedance: 47K
Local Unit Connectors: 2 x 3.5mm stereo jack socket (Line In & Line Out)
Remote Unit Connectors: 2 x 3.5mm stereo jack socket (Line/Mic In & Line Out)
Microphone Support: A microphone may be connected to the Remote Unit.
A pull-up resistor provides bias for condenser
microphone. Option to set microphone amplification to +17dB